Free Shipping In All Countries
Cart 0
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V
Battery battery charging control module power failure overcharge protection switch 6-60V

Battery battery charging control module power failure overcharge protection switch 6-60V

Regular price $19.92 Sale price $29.96 Unit price per
Tax included. Shipping calculated at checkout.

Product Description :

XY-L10A battery battery charging control module

Digital full power off overcharge protection switch 6-60V

Module highlights:

1. 6-60V any battery, lithium battery can be used;

2. LCD display, battery voltage, charge percentage and charging time at a glance;

3. The function is very powerful, it can automatically charge control, can control the charging time, and can set and upload the corresponding parameters through the serial port;

First, the function description
1. Automatic charging control function:
By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage ≤ the lower limit voltage dn, the relay is turned on, the charger starts to charge the battery; when the battery voltage ≥ the upper limit voltage UP, the relay is turned off, and an automatic charging is completed;

2. Charging time control function:

How to turn on time control?

After entering the parameter setting, if the setting parameter OP is not 0, the time control function is enabled. The default parameter of the OP is: -----h, the time control function is not enabled by default;

After the time control function is turned on (OP is not 0), when the battery voltage < lower limit voltage dn, the charger starts to charge the battery, and the system starts timing; during the timing, the battery voltage ≥ the upper limit voltage UP, the relay is turned off; if the battery voltage <Upper voltage, but the charging time OP time is up, the relay is off; if the OP time is up, the battery voltage is still <lower limit voltage dn, the relay remains on, the charging time control function is automatically turned off, and the flashing display H: ER reminds the user, time The parameter setting is unreasonable; press any key to stop flashing;

Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours.

3. Serial data upload and parameter setting function:


The system supports UART data upload and parameter setting function (TTL level);

UART: 115200, 8, 1

command

Features

On

Relay enable

Off

Relay enable off

Start

Start data reporting

Stop

Stop data reporting

Read

Get the parameters of the system

Dw10.0

Set the lower limit voltage

Up20.0

Set the upper limit voltage

Xx:xx

Set charging time, 00:00 turn off charging time control function

Data upload message format:

Battery voltage + battery percentage + charging time + charging status

12.0V, 020%, 00:10, OP

 

 

Second, the parameter settings

a) Press and hold the SET button to enter the parameter setting interface, the LCD will display SET;

b) After entering the parameter setting interface, switch the set parameters by short pressing the SET button;

c) After selecting the parameters, you can use the UP/DOWN button to set, support short press, long press (rapid increase or decrease);

d) Repeat steps b), c) if you want to set other parameters;

e) After all the parameters are set, press and hold the SET button to exit and save;

Third, the button function description

In the running interface (main interface),

Short press the SET button to display the currently set parameters;

Short press the UP button to switch between display charging percentage and charging time;

Press the DOWN button shortly to select the enable/disable relay enable. If the relay is enabled to turn off, ‘OFF’ will be displayed to remind you that the relay is off.

Press and hold the UP button to set the status of the LCD backlight (L-P), OFF: the backlight is always on, on: the backlight is automatically turned off after 5-10 minutes;

Press and hold the SET button to enter the parameter settings.

Fourth, the calculation of the voltage percentage: battery voltage / (upper limit voltage - lower limit voltage).

Five, additional features

a) Charging time recording function: When the charging time control is not turned on, the product will record a complete time. When entering the time display interface, the charging time will flash; when the time display interface is exited or the next charging is turned on (the relay is turned on) ;

b) Automatic parameter detection: When the parameter is set, when exiting, if the voltage lower limit dn ≥ upper limit voltage up, the system will flash “ERR” to indicate the alarm;

c) Battery access detection: This product is attached to the battery. If the battery is not connected, the system will display “nbE” on the lower line to remind you;

 

 

Six, common fault analysis

Q: How many V levels are suitable for use? How many V voltages does this module fit?

A: This model is suitable for use in the lowest 6V, up to 60V voltage range. The maximum expenditure level is 48V. Because the 48V battery is fully charged at 60V, it will burn when it is high. If your battery is higher than 48V, please choose other models.

Q: The relay is ringing after power-on! The indicator light flashes?

A: This is because your charging current is too large or the battery capacity is too small, it will reach the upper limit of the voltage immediately upon power-on. When the relay is disconnected, the voltage will quickly drop to the lower voltage limit, and then start charging, and cycle again and again. When you want to reduce the charging current, usually the charging current is 1 to 1.5 of the battery capacity, such as 20AH battery charging current is generally around 2-3A! Note that high current charging can cause the battery to heat up, aging, bulging or even exploding!

Q: What control method? Can I cycle automatically? Can you use the side charge? Can you limit the flow?

Answer: This is voltage control. For example, set the voltage lower limit of 12.0V, the voltage upper limit is 14.5V, and the voltage is charged to 14.5V. This voltage is cut off. The voltage is reduced to 12.0V. The relay is closed and begins to charge. The mode only turns off and on, can't limit the current, the charging current is completely dependent on your charger!

Q: Can I charge a 24V battery by inputting 12V, or can I charge a 12V battery by inputting 48V?

A: This is a simple voltage controller that only functions as a switch. It cannot be charged to charge the battery. So what kind of charger should you prepare for charging the battery? necessary!

 

Attention

 

As different computer display the colors differently,and the color maybe is little difference from the actual items,but we can guarantee the style is same,but maybe some not same performance on different bodies as on the models.Hope you can understand it.thank you

 

SHIPPING

Shipping Timeframe:

US, Australia, New Zealand: 2~3 weeks  France: 2~4 Weeks

UK, Germany, Canada: 3~5 weeks  Other European Countries: 3~5 Weeks

Asian Countries: 3~5 Weeks       Others: 3~8 Weeks·

 Items will be shipped in within 4 days after payment is received. 

Items are shipped from China using Post Air Mail Registered (HongKong Post, Sweden Post or Singapore Post).

The Parcel Status Can Be Tracked Via Post Official Website or WWW.17track.net 8-10 Days Later After Sending.The Real Delivery Date Is Subject to the Custom & Local Logistic Status.

In Case Express Service Required, Please Contact Us About the Detailed Freight.

If You Don't Receive the Item On Time, Please Take Time to Contact us.

TERMS OF SALE

We're not responsible for any custom duty or import tax.

 If you are not satisfied with the item you received, Please contact us for parcel return & payment refund.The returned parcel shouldbe sentback in original package (or well protected)in14days after the receipt.

If item is founddefective in 1 months, We will send you a replacement free of chargeor arrange the refund after the receipt of the defective item. But you have to pay for the returned freight.

We strive for 100% customer satisfaction on every sale we complete. If, for any reason you are not satisfied with your purchase, please contact us before leaving neutral or negative feedbacks.We'll work with you to solve the problem. We'll automatically leave positive feedbacks after received positive feedbacks from you.

ABOUT US

We are family owned business, and we have served thousands of customers from all over the world. Our products are direct from factory, so we can provide quality items at very competitive price.

CONTACT US

If you have any question, please contact us by the contact seller now button, leave us message or send us emails. Most emails are responded within 24 business hours. We work 5 days a week (Note: Buyers who use free email like AOL, Yahoo, the reply email may fall into your junk mail box. Please send email directly or try send email by other account).


Share this Product